Communicate with Supplier? Supplier
Doris Liang Ms. Doris Liang
What can I do for you?
Chat Now Contact Supplier
 Tel:86-0531-13001728634 Email:wei@hjcchem.com
Home > Products > Water Treatment Agent > Reverse Osmosis Water Treatment Agent > reverse osmosis cleaning agent (alkaline)
reverse osmosis cleaning agent (alkaline)
reverse osmosis cleaning agent (alkaline)
reverse osmosis cleaning agent (alkaline)
reverse osmosis cleaning agent (alkaline)
reverse osmosis cleaning agent (alkaline)
  • reverse osmosis cleaning agent (alkaline)
  • reverse osmosis cleaning agent (alkaline)
  • reverse osmosis cleaning agent (alkaline)
  • reverse osmosis cleaning agent (alkaline)
  • reverse osmosis cleaning agent (alkaline)

reverse osmosis cleaning agent (alkaline)

    Payment Type: L/C,T/T
    Incoterm: FOB,CFR,CIF,EXW
    Min. Order: 1000 Kilogram
    Delivery Time: 30 Days

Basic Info

Model No.: PO-5150

Place Of Origin: Shandong

Purity: 100%

Form: White Crystal Powder

Storage Condition: Store Below +30°C.

Certification: COA

Application: Industrial Grade

Grade: Industrial Grade

Package: 25kg/bag

Additional Info

Packaging: 25kg/bag,25kg/barrel,200kg/bag.custom made

Productivity: 10000kg/month

Brand: HUIJINCHUAN

Transportation: Ocean,Land,Air

Place of Origin: Shandong

Supply Ability: 20000kg/month

Certificate: SGS,CE,and COA of Factory

Port: Qingdao Port,Tianjin Port,Shanghai Port

Product Description

Product performance

The stability of the operation of the reverse osmosis system depends on the level of pretreatment of the raw water quality. However, in any case, after reverse osmosis for a certain period of time (usually 3-12 months), it must be contaminated to varying degrees. Chemical cleaning is a necessary means to restore membrane performance. The po-5150 reverse osmosis cleaning agent contains a unique buffer, Surfactant, chelating agent, and dispersing agent. Remove colloids, particles and organic contaminants by increasing pH, chelation, wetting and other mechanisms. After removal, the surfactant in the medicament is used to repair the reverse osmosis membrane. Excellent cleaning results can extend the run time and service life of the EDI block.

(1) Aromatic polyamide film and acetate film for all brands;

(2) Efficient removal of oil, organic matter and biological mucosa from the surface of the membrane;

(3) Improve the temperature and the effect is better;

(4) The pH of the diluent is adjusted to be maintained at 10.5 ± 0.5;

(5) Liquid medicine, which can shorten the mixing time;

(6) Better combination with PO-500 acid reverse osmosis cleaning solution


Instructions

Usually the dilution ratio is 0.1-0.5% of the entire cleaning liquid.

(1) Inspect and flush the entire EDI cleaning system to keep it clean;

(2) Before cleaning, the type of contamination of the EDI component and the cause of the contamination must be basically clarified. To basically do the right medicine, do not blindly clean. After cleaning, analyze the causes of pollution and make corresponding pre-treatment defense measures;

(3) During the cleaning process, the temperature of the cleaning solution should always be maintained within the required temperature range (15 to 38 ° C);

(4) The flow rate of cleaning should be recommended by the EDI manufacturer or pharmaceutical supplier. In addition, the flow rate is small and small, and the length of the soaking time is determined according to the pollution type and pollution degree of the EDI component. If there is no such recommendation, the technical engineers of Puno can give guidance according to the actual situation of the system;

(5) For systems with more serious pollution, it is best to consult the pharmaceutical or EDI supplier during cleaning to obtain the best cleaning solution;

(6) The system must be flushed with EDI water until it is re-used until the TDS content does not exceed 5 ppm and the pH of the water is within the normal range.

Packaging, storage and handling

Packed in plastic drums, 25kg / barrel, 200kg / barrel or according to user needs; storage and operation must use corrosion-resistant materials; stored in a cool dry place, storage period of 12 months. Wear latex gloves, safety glasses, and protective clothing. If you splash your eyes, immediately rinse your eyes with plenty of water and see a doctor quickly. Prevent spillage on the concrete floor to avoid corrosion. If the ground is eroded, rinse immediately with clean water.


reverse osmosis scale inhibitor




Looking for ideal Alkaline Cleaning Agent Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Reverse Osmosis Cleaning Agent Liquid are quality guaranteed. We are China Origin Factory of Alkaline Cleaning Agent Use. If you have any question, please feel free to contact us.

Product Categories : Water Treatment Agent > Reverse Osmosis Water Treatment Agent

Email to this supplier
  • Ms. Doris Liang
  • Your message must be between 20-8000 characters

Related Products List

Home

Phone

Skype

Inquiry